Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 87
  • Home
  • Print this page
  • Email this page
CASE REPORT
Year : 2015  |  Volume : 1  |  Issue : 2  |  Page : 121-123

A novel simplified functional impression making for prosthetic ocular rehabilitation


Department of Prosthodontics, Post Graduate Institute of Dental Sciences, Pt. B. D. Sharma University of Health Sciences, Rohtak, Haryana, India

Correspondence Address:
Manu Rathee
Department of Prosthodontics, Post Graduate Institute of Dental Sciences, Pt. B. D. Sharma University of Health Sciences, Rohtak - 124 001, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2454-3160.177948

Rights and Permissions

Successful prosthetic rehabilitation of an ocular defect can be achieved by recording the remaining orbital anatomic structure using a functional impression technique. This clinical report discusses the ocular impression making procedure in a subject with a history of failed ocular implant in eviscerated eye. The problem encountered while making a static ocular impression is a nonfunctional recording of associated musculature, making ocular prosthesis unstable. This case report presents an accurate impression making of the anophthalmic socket using a functional impression technique.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1407    
    Printed112    
    Emailed0    
    PDF Downloaded13    
    Comments [Add]    