ORIGINAL ARTICLE
Year : 2015  |  Volume : 1  |  Issue : 2  |  Page : 112-116

Retention of various overdenture posts: An in vitro study


1 Department of Dental, Civil Hospital, Hoshiarpur, India
2 Department of Pedodontic and Preventive Dentistry, Desh Bhagat Dental College and Hospital, Muktsar, Punjab, India
3 Department of Prosthodontics and Crown and Bridges, Sri Guru Ram Das Dental College and Hospital, Amritsar, Punjab, India

Correspondence Address:
Babita Karda
Street No. 1B, New Gobind Nagar, B/H - Sonalika Threshers, Jalandhar Road Hoshiarpur - 146 001, Punjab
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2454-3160.177945

Rights and Permissions

Context: Tooth retained overdenture helps to reduce the impact of some of the complete denture wearing consequences: Residual ridge resorption, loss of occlusal stability, undermined esthetic appearance, and compromised masticatory function. Aims: This in vitro study compared the retention of three prefabricated overdenture posts cemented with self-adhesive resin cement. Subjects and Methods: Thirty freshly extracted noncarious, healthy mandibular canines were sectioned 1 mm above cementoenamel junction and endodontically treated. The teeth were divided in three groups and prepared for overdenture posts: Group 1: Access post overdenture (EDS, USA), Group 2: Flexi overdenture post (EDS, USA), and Group 3: Ceka Preci-Clix overdenture (Ceka Preci-line, Germany). Posts were cemented with self-adhesive resin cement (Relyx U 100, Germany). Each tooth was positioned identically in the universal testing machine (Instron), and the amount of force necessary to remove a post from the tooth was recorded. Statistical Analysis Used: The results obtained were statistically analyzed using one-way analysis of variance and the comparisons of groups were performed using post hoc Tukey honestly significant difference test. Results: Ceka Preci-Clix overdenture post has maximum mean retention value of 171.57N and access post overdenture has minimum retention value of 98.75N. Conclusions: Ceka Preci-Clix overdenture post was more retentive (171.57) due to its parallel sided design than the other posts used in this study. Flexi overdenture post, due to its split shank threaded design, was the 2 nd most retentive post (128.88) after Ceka Preci-Clix overdenture post and access post overdenture were least retentive post (98.75) due to its thick-walled hollow design.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2996    
    Printed219    
    Emailed0    
    PDF Downloaded82    
    Comments [Add]    

Recommend this journal